Ultra-low-dose pre-shots linked to fewer wrist X‑ray retakes
A prospective clinical study published online in Radiography on 2 November 2026 reports that taking a very low-dose "pre-shot" to check positioning before a lateral wrist radiograph, cleaned up with deep learning noise reduction, was followed by a large fall in retakes.
What's new
A pre-shot is a quick check exposure taken before the diagnostic image so that the radiographer can correct positioning first. Its drawback is the extra dose. The authors tested whether a deep learning noise-reduction engine from one manufacturer (Canon's AiCE) could make a much lower-dose pre-shot good enough to judge positioning.
First, in phantom images of a lateral wrist, 15 radiological technologists rated image quality at different settings. Without noise reduction, no low-dose setting was good enough to decide on a retake. With it, 1.6 mAs (against a standard 2.8 mAs, with extra copper filtration) was rated acceptable by every rater and was chosen.
The team then compared a group X-rayed without a pre-shot (542 patients) with a group that had one (325 patients). The retake rate fell from 14.38% to 0.61%. The estimated entrance dose of the pre-shot was about 0.11 µGy, around 0.15% of the dose of a standard lateral wrist image.
The abstract does not describe the groups as randomised, so other differences between them may contribute. The study used one detector and one vendor's software, covered the wrist only, and estimated dose from phantom measurements. Our summary is based on the published abstract.
What it means for learners
- The lateral wrist is easy to get wrong. In the group without a pre-shot, about one in seven needed a retake. A true lateral matters because tilt and angulation of the distal radius are judged on it; see distal radius fractures and X-ray projections.
- Every retake is extra dose. Avoiding repeats is part of optimisation under IR(ME)R, as covered in radiation dose and protection. Good positioning is the first check in RIPE for image quality.
- One study, one vendor. Whether pre-shots are used, and how, depends on your department's equipment and protocols. Follow local practice.
Source
- Mori K, Sekiguchi R, Suzaki M, Matsukura K, Kidokoro Y, Toukai M, Tsujimoto R, Negishi T. Reducing radiographic retake rates with ultra-low dose pre-shots using deep learning-based noise reduction: a prospective clinical study. Radiography. 2026;32(8):103618. Published online 2 November 2026. doi:10.1016/j.radi.2026.103618 (phantom study plus prospective clinical comparison of 867 patients, not described as randomised; summary based on the published abstract).
Also in What's new: Radiographer commenting and image quality · UKHSA X-ray dose tables update · Ankle decision rules at triage in children.
For education only. Not a substitute for a formal report, senior review or your local policy. Never use this page to make decisions about a real patient.