Tracheostomy tube position on chest X‑ray
A tracheostomy tube is a short, curved airway that enters the trachea through a stoma in the front of the neck. On a chest X-ray you are asking three things: is the tip sitting centrally in the trachea, well above the carina? Is the tube lined up with the trachea rather than angled into its wall? And, after a new insertion, is there air where there should not be: pneumothorax, pneumomediastinum or surgical emphysema? The film is a useful check of position and complications, but it is a poor tool for judging whether the tube is working. A patient with a blocked or displaced tracheostomy needs the bedside emergency approach, not an X-ray.
Patient safety
Confirmation of tube and line position must follow your organisation's local policy, which sets who may confirm a position, what must be documented and when a radiologist reviews the film. This page explains the radiographic criteria for learning. It does not authorise anyone to confirm placement.
1. Tracheostomy or laryngectomy?
Before reading any film of a "neck breather", know which kind of neck airway the patient has, because it changes what a rescuer can do.
- Tracheostomy: an opening into the trachea, usually with a tube in it. The larynx is still present, so the upper airway (mouth and nose) normally remains connected to the lungs. In the UK National Tracheostomy Safety Project (NTSP) algorithm for a patient with a patent upper airway, oxygen is applied to both the face and the tracheostomy, and oral intubation remains a rescue option.
- Laryngectomy: the larynx has been removed and the trachea is brought out to the skin as an end stoma. The NTSP explains that these patients cannot breathe through the nose and mouth because these are no longer connected to the lungs, so oxygen by face mask will not work. Oxygen and ventilation go to the neck stoma only.
On a chest X-ray the two can look similar: a stoma in the lower neck, sometimes with a tube or a short laryngectomy tube in it. The film does not reliably tell you whether the larynx is present. The NTSP's answer is a bedhead sign for every neck-breathing patient, with separate signs and algorithms for a tracheostomy with a patent upper airway and for a laryngectomy. Check the sign and the notes, not the film.
2. What the tube looks like
Most adult tracheostomy tubes share the same basic parts. Knowing them helps you recognise the tube on the film and understand the emergency steps.
| Part | What it does | On the X-ray |
|---|---|---|
| Flange (neck plate) | Sits on the skin of the neck and is tied or taped in place, holding the tube at the stoma just in front of the trachea. | A horizontal plate or wings projected over the lower neck, often partly radiopaque. |
| Outer cannula | The curved tube that passes through the stoma and down the trachea. | A short, curved, tubular density running from the lower neck into the tracheal air column, usually with a radiopaque edge or tip. |
| Inner cannula (inner tube) | A removable liner that can be taken out and cleaned. Removing it is an early step if the tube is blocked. | Not usually distinguishable from the outer cannula. |
| Cuff | An inflatable balloon near the tip that seals the trachea for ventilation and limits aspiration. Not all tubes are cuffed. | Often hard to see on a plain film. |
| Speaking valve or cap | Fitted to the outer end in some patients to allow voice. | Outside the neck, if included at all. |
A tracheostomy tube is shorter than an endotracheal tube (ETT), and it does not run up through the larynx and mouth. If you can trace a tube from the mouth down past the larynx, it is an ETT, not a tracheostomy; see endotracheal tube position.
3. How to look
Most of these films are supine or semi-erect AP portable films on ICU or the ward. Expect the usual limits of a portable AP chest X-ray: magnification, rotation and often reduced inspiration. Then work through the device:
- Find the flange and stoma over the lower neck.
- Trace the tube into the tracheal air column. It should curve smoothly and then run down the middle of the trachea.
- Check the axis. The distal tube should lie centrally within the tracheal lumen and roughly parallel to its walls. A tip that points into the front or back wall, or a tube that crosses outside the air column, is abnormal.
- Find the tip and the carina. Measure the distance from the tip down to the carina with the PACS calliper.
- Look for air in the wrong place: pneumothorax (on a supine film think of the deep sulcus sign), pneumomediastinum and surgical emphysema in the neck and chest wall. See pneumomediastinum and surgical emphysema.
- Check every other device on the same film, especially the NG tube and any central lines, and look for new consolidation or collapse.
- Compare with the film before the tracheostomy and with any earlier tracheostomy films.
4. Where the tip should be
Key position criteria (adult)
- Tip centrally within the tracheal lumen, ending roughly halfway between the stoma and the carina (Wang et al, 2026; Radiology Masterclass describes the tip at about half the distance between the top of the tube and the carina).
- Tube aligned with the long axis of the trachea, not angled into a wall (Wang et al, 2026).
- Radiology Masterclass's worked example shows a correctly placed tracheostomy tip about 6 cm above the carina. That is one illustrated example, not a published target range: the sources read for this page do not give a fixed number of centimetres for adults.
The "halfway" rule makes sense once you picture the tube. The flange fixes the outer end at the stoma, and the tube length is chosen to reach the mid-trachea. A tip much closer to the carina risks entering a main bronchus, while a tip close to the stoma risks slipping out of the trachea into the soft tissues of the neck.
Unlike an oral ETT, a tracheostomy tube is not fixed at the mouth, so the ETT teaching that "the tip follows the chin" is not the main concern. The bigger practical issues are the angle of the tube and whether it is still in the trachea at all.
Pearl
Describe a tracheostomy tube in three parts: where the tip is relative to the carina, whether the tube is central and parallel to the trachea, and whether there is any new extra-luminal air.
Children and infants. Paediatric tracheostomy position is a specialist area and the trachea is short. In one infant series, tip-to-carina distances measured on chest X-ray differed from direct tracheoscopy by more than 2 mm in 90% of patients (Keane et al, 2021), so radiographic measurements in infants should be interpreted with caution and in line with local paediatric policy. This page does not give paediatric targets.
5. Malposition and false passage
A tracheostomy tube can be misplaced at insertion or can move later, particularly when the tube is changed, when the ties loosen, or in patients with a thick or swollen neck.
- Too deep: the tip approaches or enters a main bronchus. As with an ETT, look for collapse of the non-ventilated lung or lobe. See lobar collapse.
- Angled: the tip abuts the anterior or posterior tracheal wall. Wang et al note that misplacement or angulation can cause tracheal wall erosion and surgical emphysema.
- Displaced out of the trachea: the tube passes into the pretracheal soft tissues, a so-called false passage. Wang et al describe accidental decannulation into the pretracheal space as one consequence of malposition. On the film the tube may lie anterior to or outside the tracheal air column, often with surgical emphysema or pneumomediastinum. In a large bronchoscopically guided percutaneous series, mal-placement in the anterior mediastinum was among the significant complications (Kumar et al, 2008).
Pitfall: a "good" position on one projection
A single AP film flattens the neck. A tube lying in front of the trachea can project over the tracheal air column and look central. If the patient's ventilation, capnography or ability to pass a suction catheter does not fit with a reassuring film, believe the patient, not the image.
6. Complications after insertion
The classic post-tracheostomy film is looking for air-leak complications (pneumothorax, pneumomediastinum, surgical emphysema), malposition and new consolidation or collapse. These are real but uncommon findings, which is why the value of a routine post-procedure film has been questioned.
| Study | Population | What the post-procedure film found |
|---|---|---|
| Yeo et al, 2014 (systematic review) | Adults, surgical and percutaneous tracheostomy | Complications detected on 2.2% of films after surgical and 3.2% after percutaneous tracheostomy; only 0.7% and 1.8% respectively required intervention. |
| Kumar et al, 2008 | 345 adults, bronchoscopically guided percutaneous tracheostomy | New abnormalities on 8 (2.3%) immediate films, and only one after an uncomplicated procedure. |
| Tobler et al, 2012 | 255 adults, trauma centre | New significant findings in 4.3%, including surgical emphysema, pneumothorax and consolidation; management changes were driven by clinical findings. |
Taken together, these studies suggest that new X-ray complications after tracheostomy appear on roughly 2–4% of adult post-procedure films across these series (2.2–3.2% in Yeo et al, 2.3% in Kumar et al, 4.3% in Tobler et al) [VARIES], and that the film is most useful after a technically difficult procedure or when the patient deteriorates. Yeo et al also list higher-risk groups for percutaneous tracheostomy, including trauma, high ventilatory requirements, difficult procedures and procedures done without bronchoscopic guidance. Whether a routine film is taken is a local policy decision.
What each complication looks like
- Surgical (subcutaneous) emphysema: streaky lucencies outlining the muscles and fat planes of the neck and chest wall. New, increasing or extensive emphysema after insertion should prompt review of the tube position.
- Pneumomediastinum: lucent lines alongside the mediastinal borders, the trachea or the aortic knuckle, sometimes with the continuous diaphragm sign. Air may track from the neck. It can indicate a tracheal wall injury or a false passage.
- Pneumothorax: a visible pleural edge on an erect film, or the deep sulcus sign and a hyperlucent hemithorax on a supine film. In a ventilated patient it can progress to tension. See pneumothorax.
- Collapse or consolidation: from a deep tube, secretions, aspiration or bleeding into the airway.
7. The film and the airway emergency
Tracheostomy and laryngectomy airway emergencies are uncommon but cause significant harm and death, which led to the multidisciplinary NTSP guidelines published in Anaesthesia in 2012 (McGrath et al). Their algorithms are designed to be followed by first responders, starting with simple, common, fixable problems.
The NTSP emergency algorithm for a tracheostomy with a patent upper airway works through these steps, in this order of thinking:
- Call for airway expert help and look, listen and feel at both the mouth and the tracheostomy, using waveform capnography where available.
- Apply high-flow oxygen to both the face and the tracheostomy.
- Assess tube patency: remove any speaking valve or cap, remove the inner tube, and try to pass a suction catheter.
- If a suction catheter will not pass, deflate the cuff (if present) and reassess.
- If the patient is still not stable or improving, remove the tracheostomy tube, then reassess.
- If the patient is not breathing, call the resuscitation team and start CPR if there is no pulse. The algorithm then moves to primary emergency oxygenation by standard oral airway methods (covering the stoma) or via the stoma, and to secondary emergency oxygenation by oral or stoma intubation, which are expert steps.
Note what is missing: there is no X-ray step. A blocked or displaced tracheostomy is diagnosed and treated at the bedside. A chest X-ray belongs after the airway is secure, to check the new tube position and look for complications. For a laryngectomy patient, the separate NTSP laryngectomy algorithm applies, and face and mouth oxygen will not reach the lungs.
Pearl
The NTSP algorithm uses capnography at every reassessment because exhaled carbon dioxide indicates a patent or partially patent airway. It is a bedside test of function; the film is a test of anatomy.
8. Pitfalls
- Calling an ETT a tracheostomy or vice versa. Trace the tube: an ETT comes from the mouth, a tracheostomy tube from the front of the neck.
- Assuming the larynx is present. The film cannot tell a tracheostomy from a laryngectomy reliably. Check the bedhead sign and records.
- Measuring on a rotated film. Rotation shifts the apparent position of the tube relative to the tracheal air column. Judge alignment with care, and compare with earlier films.
- Expecting the cuff to tell you the pressure. Cuffs are often difficult to judge on plain film (Radiology Masterclass notes that ETT cuffs are not usually visible). Cuff pressure is measured at the bedside, not judged from the X-ray.
- Treating a reassuring film as proof the airway is working. It is not. Patency is a bedside judgement.
Red flags: act now
Escalate immediately
- Any patient with a tracheostomy or laryngectomy who is in respiratory distress: follow the NTSP bedside algorithm and call for airway expert help. Do not wait for a film.
- Tube tip outside the tracheal air column, or a tube that has moved substantially since the last film: possible false passage or displacement.
- Tip at or very close to the carina, especially with new collapse.
- New or increasing pneumomediastinum or surgical emphysema after insertion or a tube change.
- New pneumothorax in a ventilated patient.
What to focus on, by role
| Role | Priorities |
|---|---|
| Medical student | Recognise a tracheostomy tube, know the "halfway between stoma and carina" rule, and know the difference between a tracheostomy and a laryngectomy. |
| Nurse | Check the bedhead sign, emergency equipment and tube type at the start of each shift. Know the first NTSP steps: call for help, oxygen to face and stoma (tracheostomy) or stoma only (laryngectomy), remove the inner tube and pass a suction catheter. |
| Junior doctor | Review post-insertion and post-change films for tip position, alignment and extra-luminal air, and check all other devices. Escalate any doubt about position to the team that placed the tube. |
| Radiographer | Include the lower neck, the whole tube and the carina, keep the patient as straight as is safe to limit rotation, and flag obvious extra-luminal air or a tube outside the trachea according to local protocol. |
| Advanced / FRCR | False passage, tracheal wall injury, angulation against the tracheal wall, paediatric tubes and the limits of routine post-procedure imaging. |
Terms such as stoma, flange and false passage are in the glossary.
Practise on lines and tubes films →
References
- McGrath BA, Bates L, Atkinson D, Moore JA; National Tracheostomy Safety Project. Multidisciplinary guidelines for the management of tracheostomy and laryngectomy airway emergencies. Anaesthesia 2012;67(9):1025–1041. doi:10.1111/j.1365-2044.2012.07217.x
- National Tracheostomy Safety Project. Emergency tracheostomy management: patent upper airway algorithm, and Emergency care: tracheostomy and laryngectomy. tracheostomy.org.uk
- Radiology Masterclass. Chest X-ray: endotracheal and tracheostomy tube anatomy. radiologymasterclass.co.uk
- Wang J, He L, Schooler GR, Towbin AJ, et al. Review of artificial intelligence for automated assessment of lines, drains, and airways on pediatric and adult chest radiographs. Pediatr Rep 2026;18(5):119. doi:10.3390/pediatric18050119
- Yeo WX, Phua CQ, Lo S. Is routine chest X-ray after surgical and percutaneous tracheostomy necessary in adults: a systemic review of the current literature. Clin Otolaryngol 2014;39(2):79–88. doi:10.1111/coa.12233
- Kumar VM, Grant CA, Hughes MW, et al. Role of routine chest radiography after percutaneous dilatational tracheostomy. Br J Anaesth 2008;100(5):663–666. doi:10.1093/bja/aen038
- Tobler WD, Mella JR, Ng J, et al. Chest X-ray after tracheostomy is not necessary unless clinically indicated. World J Surg 2012;36(2):266–269. doi:10.1007/s00268-011-1380-4
- Keane A, Saadi RA, Slonimsky E, Wilson M, May J. Comparison of tracheoscopy and portable chest X-ray in the evaluation of infant tracheostomy tube position. Int J Pediatr Otorhinolaryngol 2021;141:110566. doi:10.1016/j.ijporl.2020.110566
For education only. Not a substitute for a formal report, senior review or your local policy. Never use this page to make decisions about a real patient.