NG tube check X‑rays: what a national audit in Brunei changed

A national clinical audit published online in the Journal of Medical Imaging and Radiation Sciences on 14 November 2026 looked at chest X-rays taken to confirm nasogastric (NG) tube position in adults across all public hospitals in Brunei Darussalam. After three changes to practice, film quality, report quality and documented escalation of misplaced tubes all improved; the time taken to get the X-ray did not.

What's new

The audit included adults aged 18 and over who had a chest X-ray to check NG tube position. The first cycle covered one month in June 2025. The team measured how quickly the film was taken, whether it was technically adequate, what the radiologist's report said, and whether a misplaced tube was documented as communicated to the referring team or ward.

Three changes followed: a departmental guideline, training for radiographers, and a standard reporting template for radiologists. Re-audits were done in January and April 2026. The three cycles included 75, 98 and 92 X-rays. Technical adequacy, report adequacy and documentation of communicating a misplaced tube all improved significantly (p < 0.05) after the changes.

Most films were taken within 4 hours in every cycle (94.7%, 94.9% and 88.0%), and timeliness did not improve after the changes. The authors suggest regular reminders and clear pathways for NG tube imaging and for acting on a misplaced tube. This is an audit in one country's public hospitals, not a trial. Our summary is based on the published abstract, which does not give the detailed audit standards or the per-cycle figures for each quality domain.

What it means for learners

  • A check film has to show the whole tube. The audit treated technical adequacy as a safety measure in its own right. Know what an adequate film looks like and the four criteria for a safe position in NG tube position on X-ray.
  • The report must answer the question. A standard template was one of the three changes. If a report does not say clearly where the tube tip is, it is not a confirmation of position; see the pitfalls section of the NG tube module.
  • Finding a misplaced tube is only half the job. The audit measured whether communication of a misplaced tube was documented. Know your local escalation route before you need it, and follow your local policy at all times.
  • Image quality is a shared skill. For a general approach to judging whether a chest film is adequate, see X-ray image quality (RIPE).

Source

  • Pg Suhaimi AMA, Lim KC, Abdullah SFD, Zulkipli IM. Chest radiographic confirmation of nasogastric tube position in adults: a national clinical audit of patient safety and quality improvement outcomes in Brunei Darussalam. Journal of Medical Imaging and Radiation Sciences. 2026;58(1):102618. Published online 14 November 2026. doi:10.1016/j.jmir.2026.102618 (three-cycle national clinical audit; summary based on the published abstract).

Also in What's new: NG tubes: pH 4.5 cut-off and X-ray use · MHRA: NGPod pH devices withdrawn.

For education only. Not a substitute for a formal report, senior review or your local policy. Never use this page to make decisions about a real patient.