Hip replacement on X‑ray
A hip replacement (hip arthroplasty) swaps part or all of the hip joint for an implant. It is most often done for advanced osteoarthritis, and is also used for many patients with a hip fracture. The plain radiograph remains the main follow-up test: cheap, free of metal artefact and easy to compare over time. This page covers how to recognise the main implant types, how to review the film in a fixed order, and what the important complications look like: dislocation, periprosthetic fracture, loosening, wear, infection and heterotopic ossification.
1. Types of hip replacement
Name what is in the hip first: each design has its own normal appearance.
| Type | What is replaced | What you see |
|---|---|---|
| Unipolar hemiarthroplasty | Femoral head and neck | A femoral stem with a fixed metal head sitting directly in the patient's own acetabulum. |
| Bipolar hemiarthroplasty | Femoral head and neck | A stem and small head inside a larger metal cup lined with polyethylene; the cup moves within the native acetabulum. |
| Total hip arthroplasty (THA) | Femoral head and neck and the acetabulum | A stem and head plus an acetabular cup (shell), often with a liner and sometimes screws. |
| Resurfacing | The femoral head surface (and in a total resurfacing, the acetabulum too); the femoral neck is kept | A metal cap over the femoral head, with the native femoral neck still present. |
A hemiarthroplasty keeps the native acetabulum, so it is used when the acetabulum is healthy, typically after a femoral neck fracture. Whether a fractured hip should get a hemiarthroplasty or a total hip replacement is still debated.
Fixation. Either component can be cemented or uncemented (cementless):
- Cemented: acrylic bone cement is made radio-opaque with barium or zirconium, so you see a dense white mantle between implant and bone. A complete femoral cement mantle of 2–3 mm is linked with good long-term results; there is no agreed ideal thickness for the acetabular mantle.
- Uncemented: a slightly oversized, porous-coated stem or cup is press-fitted into bone, which then grows onto the surface. No cement is visible.
- Hybrid: cemented stem with an uncemented cup. Reverse hybrid: uncemented stem with a cemented cup.
Bearing surfaces matter too. Metal and ceramic are radio-opaque; polyethylene is radiolucent, so a polyethylene liner shows as a dark gap between the head and the metal shell. A metal-on-metal bearing has no such gap.
2. How to review the film
Most complications are recognised by change, so the single most useful step is to put the current film next to the previous ones, ideally including an early postoperative baseline. A recovery-room film is a poor baseline. Vanrusselt and colleagues suggest a standing AP pelvis centred on the symphysis, hips extended and internally rotated, so that the whole implant and all the cement are included, with a lateral view to assess cup anteversion.
A practical order:
- Quality and coverage. Is the whole stem tip and cement plug on the film? A fracture or lucency at the tip is easy to cut off. Check rotation and exposure.
- Name the implant: hemi or total, cemented or not, bearing type, any screws, wires or cables from earlier surgery.
- Is it located? The head should sit concentrically in the cup (or native acetabulum).
- Position: cup inclination, stem alignment, centre of rotation and leg length (section 3).
- The interfaces: follow the bone–cement, cement–implant or bone–implant line all the way round both components, zone by zone (section 6).
- Wear: is the head still centred in the cup? (section 7).
- The bone: cortex for fracture lines, periosteal reaction, new lytic areas.
- The implant itself: fractured stem, broken screws or wires, a displaced liner.
- Soft tissues: new bone, gas, metal debris.
- The rest of the pelvis and the other hip: do not stop at the implant (see pelvic fractures and how to read a skeletal X-ray).
3. Component position and leg length
Measured on the AP pelvis; treat them as description, not a pass/fail test.
Key measurements
- Acetabular inclination (cup abduction angle): the angle between a line across the rim of the cup and a transverse pelvic line such as the line joining the ischial tuberosities. The often-quoted Lewinnek "safe zone" is 40° ± 10° of inclination and 15° ± 10° of anteversion, i.e. 30–50° and 5–25°; a radiology review gives the same ranges as normal. Steeper cups are associated with dislocation.
- Acetabular anteversion is judged on a lateral view (true or cross-table lateral). Retroversion predisposes to dislocation.
- Leg length: draw a line through the inferior edges of both teardrops, then measure perpendicular to it from each lesser trochanter; the difference is the leg-length discrepancy. A discrepancy under about 1 cm is generally well tolerated (two reviews agree).
- Centre of rotation: the centre of the femoral head compared with the teardrop (horizontal) and the ischial tuberosity line (vertical); ideally it matches the other hip.
- Stem: should lie in neutral alignment with the femoral shaft, tip central in the canal. Varus positioning is linked with stem failure.
Pitfall: the safe zone is not a guarantee
Lewinnek measured the cup on supine films taken perpendicular to the anterior pelvic plane, and the safe zone rested on only 9 dislocations. A review of 147 later papers found only 11% used it the way it was defined; standing films tend to show higher inclination and anteversion, and pelvic tilt changes apparent anteversion. Report the angle and the view used.
4. Dislocation
Dislocation is one of the most common complications of a hip replacement, alongside infection and aseptic loosening. Reported rates after primary THA range from 0.5% to 10%, and most dislocations happen early, when the patient first starts weight-bearing. After THA performed for a femoral neck fracture, a narrative review put the rate at 2–7%, with pooled rates higher for the posterior than the anterior surgical approach (5.2% vs 2.1% in the studies it gathered) [VARIES].
- On the AP: the prosthetic head is no longer concentric with the cup (or, with a hemiarthroplasty, with the native acetabulum).
- Say which way: describe the direction of displacement; an orthogonal (lateral) view helps show whether the head lies in front of or behind the cup.
- Look for a cause: a steep or retroverted cup, a changed centre of rotation, a fractured greater trochanter, a broken or displaced liner, or a loose cup that has moved.
- After reduction: check the head is concentric again and that nothing new has broken.
- Bipolar hemiarthroplasty: the head and its outer cup can dislocate together from the native acetabulum.
5. Periprosthetic fracture: the Vancouver classification
Fractures happen more often around the femoral component than the acetabulum, either during surgery or later. In the data quoted by Bissias and colleagues, most postoperative fractures followed a low-energy injury such as a fall, and a few were spontaneous. A meta-analysis of almost 600,000 hip arthroplasties found a pooled incidence of postoperative femoral periprosthetic fracture of 0.71%, with individual studies reporting 0.045–4.1% [VARIES]. Risk was higher in women, after revision surgery (about three times) and in rheumatoid arthritis, and lower with cemented fixation.
The Vancouver classification (Duncan and Masri) sorts postoperative femoral fractures by where they are and whether the stem is still fixed:
| Type | Where | Detail |
|---|---|---|
| A | Trochanteric region | AG: greater trochanter; AL: lesser trochanter. |
| B1 | Around or just below the stem tip | Stem well fixed. |
| B2 | Around or just below the stem tip | Stem loose, bone stock adequate. |
| B3 | Around or just below the stem tip | Stem loose with poor bone stock. |
| C | Well below the stem | The implant is not involved. |
The distinction between B1 and B2/B3 matters because a loose stem generally means revising the stem is considered, rather than fixing the fracture alone. Look for evidence that the stem was already loose, such as wide or progressive lucent lines, and compare its position with the previous film. The boundary between B2 and B3 (how poor is "poor bone stock") is not well defined, so classification can be subjective. In the Swedish registry data quoted by Fink and Hoyka, B3 fractures were 4.1% of periprosthetic femoral fractures.
Pearl
Postoperative femoral fractures typically (not always) occur at the level of the stem tip, so always make sure the whole stem and the bone beyond it are on the film.
6. Lucent lines, loosening and the zones
Lucencies are described by zone so they can be tracked:
- Gruen zones (femur, 1–7) on the AP: zones 1–3 run down the lateral side of the stem from the greater trochanter, zone 4 is the tip, and zones 5–7 run back up the medial side to the calcar near the lesser trochanter.
- DeLee and Charnley zones (acetabulum, I–III): the bone around the cup is divided into three zones.
Aseptic loosening is driven mostly by wear particles: macrophages react to the debris, a foreign-body granulomatous membrane forms and the implant separates from bone. On the film this is a lucent zone at the bone–cement or bone–implant interface.
Not every lucent line is loosening. A thin lucency under 2 mm with a fine sclerotic edge is common: around cement it reflects a stable fibrous membrane, and along the smooth part of an uncemented stem it reflects fibrous rather than bony ingrowth. As a rule of thumb, lucency wider than 2 mm, or any lucency that is getting wider on serial films, is abnormal. For uncemented cups, a complete lucent line ≥ 2 mm across all three DeLee–Charnley zones is used in studies as a radiographic criterion for loosening (two sources agree on the 2 mm figure). Movement of a component compared with earlier films (migration) also suggests loosening, although small migrations are hard to see on plain films.
Pitfall
A single film cannot tell you whether a line is progressing. Some modern porous cups commonly show thin, non-progressive radiolucent lines without being loose. Describe the zone and width, compare with the earliest film you can find, and let progression drive the conclusion.
7. Wear and osteolysis
With a polyethylene liner, the gap between the metal head and the metal shell is normally even all the way round. If the head sits eccentrically in the cup, for example displaced upwards (cranially), the liner has worn: an asymmetric head position is a definite sign of polyethylene wear.
Wear particles drive osteolysis and aseptic loosening (section 6), so wear and new or enlarging lucent areas around either component should be reported together, even if the patient is comfortable.
Metal-on-metal bearings can provoke an adverse reaction to metal debris (including pseudotumour). The radiograph is usually normal in this setting; occasionally there is loosening, dense metallic specks in the soft tissues or, around a resurfacing, pressure erosion of the cortex. A normal radiograph does not exclude it.
8. Infection
Periprosthetic joint infection is uncommon but serious, affecting about 1–2% of hip replacements (two reviews agree), and more often after revision surgery. The X-ray is usually the first test but is often normal or non-specific, and septic and aseptic loosening can look identical, especially without previous films.
- Features that should raise suspicion: periosteal reaction along the femur, lucency or osteolysis that appears or progresses quickly between films, and early loosening.
- Gas in the soft tissues is expected just after surgery; gas persisting beyond about 14 days should prompt concern for infection (evidence comes mainly from knee replacements).
- A normal film does not exclude infection. If it is suspected clinically (pain, swelling, redness or warmth, fever, wound drainage or a sinus), refer to the orthopaedic team; diagnosis rests on aspiration and other tests, with ultrasound, MRI or nuclear medicine as needed.
Compare with osteomyelitis and septic arthritis in native bone.
9. Heterotopic ossification: Brooker classes
Heterotopic ossification (HO) is bone forming in the soft tissues around the hip after surgery. It can be seen on X-ray or CT from about 6 weeks after the operation. Reported rates vary widely: one radiology review says up to half of patients, and a 2026 review found ranges of roughly 10–85% depending on the surgical approach [VARIES]. Most is mild; clinically relevant HO is far less common.
| Brooker class | Appearance on the AP film |
|---|---|
| 1 | Isolated islands of bone in the soft tissues around the hip. |
| 2 | Bone spurs from the pelvis or femur, with at least 1 cm between opposing surfaces. |
| 3 | Bone spurs from the pelvis or femur with less than 1 cm between opposing surfaces. |
| 4 | Apparent bony ankylosis (bridging bone across the hip). |
Classes 3 and 4 are regarded as clinically relevant and may limit flexion and abduction. Reported risk factors include male sex and certain surgical approaches.
10. Normal findings that look abnormal
- Stress shielding: the stem takes load away from the proximal femur, so bone thins (most often in Gruen zone 1) while the cortex further down thickens. This reflects a stable, well-fixed stem, not a complication.
- Spot welds: small bridges of new bone from the inner cortex to an uncemented stem; a strong sign of stability.
- Pedestal: a sclerotic bony shelf across the canal just below the tip of an uncemented stem (zone 4). Its link with loosening is uncertain; mention it and compare.
- Thin, stable lucent lines under 2 mm with a sclerotic edge (section 6).
- Fractured implant: rare, but stems can snap from metal fatigue, typically when the stem is fixed distally but loose proximally. Check the metal itself, not just the bone.
Red flags: act now
Red flag
- Dislocated hip replacement: head not concentric with the cup. Urgent orthopaedic referral for reduction, and look for a cause (cup position, fracture, broken liner).
- Periprosthetic fracture after a fall: refer to the orthopaedic team; image the whole stem and the femur beyond it.
- Signs that may mean infection: periosteal reaction, rapidly progressive lucency, soft-tissue gas weeks after surgery, or a normal film in a patient who is unwell with a painful or discharging hip.
- New lucency, migration or subsidence compared with the previous film, or a broken implant: flag it to the orthopaedic team even if the patient seems well.
What to focus on, by role
| Role | Focus |
|---|---|
| Student | Tell a hemiarthroplasty from a total hip replacement and cemented from uncemented; know that comparison with old films is the key step. |
| Nurse | Dislocation and periprosthetic fracture are the urgent findings; know how to escalate quickly, and that infection can be present with a normal film. |
| Junior doctor | Spot dislocation and periprosthetic fracture, include the whole stem, and do not let a normal film reassure you if infection is suspected clinically. |
| Radiographer | Include the whole implant, cement and stem tip; reproduce positioning so serial films can be compared; add a lateral when dislocation is suspected. |
| Advanced / FRCR | Gruen and DeLee–Charnley zones, the Vancouver classification and what it means for management, the limits of cup-angle measurements, metal debris and when to recommend cross-sectional or nuclear imaging. |
See also the glossary.
Practise on real lower-limb X-rays →
References
- Vanrusselt J, Vansevenant M, Vanderschueren G, Vanhoenacker F. Postoperative radiograph of the hip arthroplasty: what the radiologist should know. Insights Imaging 2015;6(6):591–600. doi:10.1007/s13244-015-0438-5
- Burapachaisri A, Elbuluk A, Abotsi E, et al. Lewinnek safe zone references are frequently misquoted. Arthroplast Today 2020;6(4):945–953. doi:10.1016/j.artd.2020.09.011
- Bianco Prevot L, Tronconi LP, Bolcato V, et al. Leg length discrepancy after total hip arthroplasty: a review of clinical assessments, imaging diagnostics, and medico-legal implications. Healthcare (Basel) 2025;13(12):1358. doi:10.3390/healthcare13121358
- Skotidis E, Bekas K, Kechagias I, et al. Dislocation of total hip arthroplasty of femoral neck fracture in the elderly: a narrative review. Cureus 2023;15(10):e46307. doi:10.7759/cureus.46307
- Bissias C, Kaspiris A, Kalogeropoulos A, et al. Factors affecting the incidence of postoperative periprosthetic fractures following primary and revision hip arthroplasty: a systematic review and meta-analysis. J Orthop Surg Res 2021;16(1):15. doi:10.1186/s13018-020-02152-0; and Fink B, Hoyka M. Vancouver B3 periprosthetic fractures of the femur: options for treatment. Arch Orthop Trauma Surg 2026;146. doi:10.1007/s00402-026-06219-1
- Ohta Y, Sugama R, Minoda Y, et al. Highly porous titanium cups frequently presenting with radiolucent lines in cementless primary total hip arthroplasty: a retrospective cohort study. J Clin Med 2024;13(11):3297. doi:10.3390/jcm13113297
- Hoveidaei A, Tavakoli Y, Ramezanpour MR, et al. Imaging in periprosthetic joint infection diagnosis: a comprehensive review. Microorganisms 2024;13(1):10. doi:10.3390/microorganisms13010010
- Buchanan C, Culler MW, Poursalehian M, et al. Heterotopic ossification following total hip arthroplasty: a contemporary approach-based review for surgeons utilizing the direct anterior approach. Arthroplast Today 2026;40:102110. doi:10.1016/j.artd.2026.102110
For education only. Not a substitute for a formal report, senior review or your local policy. Never use this page to make decisions about a real patient.