Chest X‑ray AI for suspected lung cancer: how the settings change what it catches
A study from NHS Greater Glasgow and Clyde, published in Insights into Imaging on 31 October 2026, tested how a commercial chest X-ray AI should be set up to flag films with an urgent suspicion of lung cancer. With the features and thresholds first chosen, it flagged fewer than half of the films that radiologists judged suspicious. A locally tuned model did much better, but how many cases it caught depended heavily on how many films it was allowed to flag.
What's new
The AI (qXR, version 4.0) gives a separate probability score for each of 22 findings, such as "mass", "nodule" or "cavity". It has no single "suspicious for cancer" output, so a hospital has to decide which scores to combine and where to set the cut-off. The team used about 2,900 consecutive adult GP and outpatient chest X-rays collected prospectively in 2023–24, plus 983 earlier outpatient and inpatient films for validation. The reference standard was double reading by radiologists on a research platform, who recorded whether each film raised an urgent suspicion of cancer. About 8% of the prospective films and 9.8% of the validation films did (Table 1).
The first set-up used five findings chosen by radiologists with the vendor (mass, nodule, cavity, hilar enlargement, mediastinal widening), each with its own threshold. Sensitivity was 49.7%, 42.9% and 49.0% in the three datasets (Table 4). Combining findings into one weighted score worked better. The best model, picked by statistical methods, used consolidation, nodule, tuberculosis and cavity. "Mass" dropped out. The authors explain that the AI's labels reflect how its training images were labelled, not the clinical meaning of the word.
The trade-off is the key result. In the prospective test set, the four-feature model at its statistically optimal threshold caught 83.1% of suspicious films but flagged 23.8% of all films. Capped at a 15% flag rate (set by local reporting capacity), it caught 59.7% and flagged 12.5% (Table 4). The same cap, set on GP and outpatient films, flagged 25.8% of the validation set, which included inpatients.
Limits: this is one product in one health board, and the authors say their numbers do not generalise. The reference radiologists had no clinical details or prior films, so old or known abnormalities counted as suspicious. The study was funded partly by the AI vendor and the Scottish Government, and one author works for the vendor.
What it means for learners
- An AI flag is not a diagnosis. Even the best set-up had a positive predictive value of about 22–38% across datasets and thresholds, so most flagged films were not judged suspicious. A flag means "look now". It does not mean "cancer". The patterns that matter are in lung nodules and masses.
- Sensitivity depends on the threshold. Flagging fewer films to protect reporting capacity meant missing more cancers. Whenever you read a headline accuracy figure for an AI tool, ask what threshold and flag rate it was measured at.
- Populations change performance. A threshold tuned on GP referrals behaved differently on inpatient films. Inpatient films are more often AP and portable and show more acute disease. See portable AP chest X-rays.
- Comparison with old films still matters. Readers without prior imaging called old abnormalities suspicious. Checking previous films is a basic step in reading a chest X-ray.
Source
- Duncan SF, Dudman K, Odigbo S, Perdomo Lampignano J, Kumar S, Hawkins N, McConnachie A, Maclay JD, Stobo DB, Hall M, Lowe DJ. Flagging urgent suspicion of lung cancer with AI CXR algorithms: optimising feature selection and performance. Insights into Imaging. 2026;17:272. Published online 31 October 2026. doi:10.1186/s13244-026-02438-7 (open access; summary based on the full text, part of the RADICAL study, NCT06044454; single health board, one commercial product).
Also in What's new: Commercial AI for lung nodules on chest X-ray: a review · RCR guidance on AI in reporting workflows.
For education only. Not a substitute for a formal report, senior review or your local policy. Never use this page to make decisions about a real patient.